Large thermocouple similar to modelAKK DIN EN 50446
straight thermocouple with ceramic protection tube, metallic holding tube (with union nut), connection head in Form A, high-grade thermocouple and platinum protection sleeve as exchangeable protection tube

  • Process connection via holding tube with separate stop flange, gas-tight threaded socket or welded-on flange.
  • Area of application: Glass industry.
  • Measuring range up to 1600°C depending on thermocouple and alloy of Pt sleeve.
  • PT ceramic of C 799, preferred diameter 10 mm with Pt sleeve Ø 11.2 or 12.0 mm.
  • 1, 2 or 3 thermocouples according to DIN EN 60584-1, in ceramic I-rod, with different optional installation heights.
  • Advantage: Good service life, Pt-PT secured against "falling down" and exchangeable, suitable as matrix measurement for recording the exact temperature distribution directly in the liquid glass.
  • By recycling the precious metals, costs can be reduced for the replacement of new sensors.

Online request / Configurator

TC with neck tube, interchangeable platinium tip and noble TC wire
Norminal length NL (4 digits) e.g. 0710 = 710 mm
NT 4 digits e.g. 80 = 0080mm
Länge 4 Stellen in mm

Your choice

Your note