Large thermocouple model AKK according to DIN EN 50446
straight thermocouple with ceramic protection tube, metallic holding tube, connection head in model A and thermocouple wire
- Under certain conditions, use in hazardous areas is possible on request.
- Process connection via holding tube with separate stop flange, gas-tight threaded socket or welded-on flange.
- Area of application: Glass industry, steel/iron, aluminium/non-ferrous metal industry, industrial furnace construction, automotive industry, heat treatment, plant/mechanical engineering, energy, waste incineration/recycling, cement/building materials.
- Measuring range depending on ceramic, thermocouple and with inner tube up to 1600°C.
- Ceramic C 530, C 610 or C 799, preferred diameter 15 or 24 mm.
- 1, 2 or 3 thermocouples according to DIN EN 60584-1, in ceramic I-rod, with different optional installation heights.
- For comparison measurements, also with optional test hole.
- On request with calibration (also according to AMS 2750 or CQI 9) in our laboratory accredited according to DIN EN 17025 (measured variable temperature)