Large thermocouple model AM according to DIN EN 50446
Straight thermocouple with metal protection tube, connection head in Form A and MIT measuring insert (model AM)
- Under certain conditions, use in hazardous areas is possible on request.
- Process connection with separate stop flange, gas-tight threaded socket or welded-on flange.
- Area of application: Glass industry, steel/iron, aluminium/non-ferrous metal industry, industrial furnace construction, automotive industry, heat treatment, plant/mechanical engineering, energy, waste incineration/recycling, cement/building materials.
- Measuring range up to 1200°C depending on protection tube material and thermocouple.
- Preferred protection tube material 1.4841, preferred diameter 15 or 22 mm.
- Measuring insert exchangeable similar to DIN 43735.
- Thermocouples according to DIN EN 60584-1, insulated welded.
- For comparison measurements, also with optional test hole.
- On request with calibration (also according to AMS 2750 or CQI 9) in our laboratory accredited according to DIN EN 17025 (measured variable temperature)