MIT assembly model D
Bendable mineral insolated thermocouple assembly with cable and free ends
- Note: also available as type-tested Ex i version in accordance with
ATEX and IECEx for measuring in zone 0,
Type in Ex operating instructions manual TR14-O, Ex ia IIC T1...T6 Ga
or Ex ia IIIC T135 °C Da. - Area of application: this sensor enables temperature measurement in hard-to-reach places, e.g. in plant and pipeline construction for industry and development.
- Recommended sheath diameters 0.25.0 mm to 6 mm.
- Sheathed cable according to IEC / EN 61515.
- Operating temperature per thermocouple type and diameter up to 1100 °C at the measuring tip.
- Thermocouples according to IEC / EN 60584-1, insulated or welded to the floor.
- Connection cable according to IEC / DIN 60584-3 PVC, silicone, PTFE, FEP or glass fibre insulated.