mineral insolated thermocouple assembly according to or similar to DIN 43772
MIT with flange protection shell form 2F
- Note: also available as type-tested Ex i version in accordance with
ATEX and IECEx for measuring in zone 0,
Type in Ex operating instructions TR-E, Ex ia IIC T1...T6 Ga/Gb
or Ex ia IIIC T135 °C Da/Db. - Process connection: Blind flange according to or similar to DIN EN 1092-1 type 05 or ASME B 16.5.
- Area of application: Autoclaves, machine and plant construction, chemical, food and beverage industry, energy and power plant technology, sanitary, heating and air-conditioning technology.
- Measuring range depending on thermocouple -50 to 1100°C, also from -196 °C on request.
- Standard material of protective fitting 1.4571, preferred diameter 9 or 11 mm.
- Measuring insert exchangeable in accordance with DIN 43735.
- Thermocouples according to IEC / EN 60584-1, insulated or welded to the floor.
- Also with optional directly mounted transmitter.