Mineral insolated thermocouple assembly according or similar to DIN 43772
MIT with protection shell form 3GoH (with "Namur" tapered measuring tip, faster responce time)
- Note: also available as type-tested Ex i version in accordance with
ATEX and IECEx for measuring in zone 0,
Type in Ex operating instructions manual TR15-G, Ex ia IIC T1...T6 Ga/Gb
or Ex ia IIIC T135 °C Da/Db. - Process connection: Double nipple with all common threads, preferred thread G1/2".
- Area of application: Autoclaves, machine and plant construction, chemical, food and beverage industry, energy and power plant technology, sanitary, heating and air-conditioning technology.
- Measuring range depending on thermocouple -50 to 1100°C.
Note: Use only at non-critical process temperature due to "low" temperature decoupling via the double nipple - Standard material of protective fitting 1.4571, preferred diameter 12 to 9 mm or 14 to 11 mm .
- Measuring insert exchangeable in accordance with DIN 43735.
- Thermocouples according to IEC / EN 60584-1, insulated or welded to the floor.
- Also with optional directly mounted transmitter.