Mineral insolated thermocouple measuring insert form BM without socket with free ends
MIT measuring insert, prepared for installation of head transmitter
- Note: also available as type-tested Ex i version in accordance with
ATEX and IECEx for measuring in zone 1,
Type in Ex operating instructions manual TR14-X-Q, Ex ia IIC T1...T6 Gb
or Ex ia IIIC T135 °C Db. - Area of application: as exchangeable measuring insert in protective fittings with connection heads Form B.
- Recommended sheath diameter 3.6 or 8 mm.
- Sheathed material according to DIN EN 61515.
- Operating temperature depending on thermocouple type and diameter -200 °C to 1100 °C at the measuring tip.
- Thermocouples in accordance with DIN EN 60584-1, insulated or welded to the floor.
- With optional directly mounted transmitter.